Hp compaq proliant dl380 manual




















The access panel slides to a closed position. Use the T Torx screwdriver attached to the rear of the server to tighten the security screw on the hood latch. Power down the server on page Remove the access panel on page Disconnect any internal or external cables connected to any existing expansion boards. Press the blue button to release the black knob. Turn the black knob counter-clockwise.

Align the PCI riser cage with the chassis and slide it into place. Tighten the thumbscrews to secure the PCI riser cage:. Press down the black knob while turning clockwise, until fully tightened.

While holding the black knob and pressing down, press and release the blue button to lower the black knob to the locked position. Connect any required internal cables to the expansion board. Refer to the documentation that ships with the expansion board. Install the access panel on page Install the server into the rack. Connect any required external cables to the expansion board.

Power up the server on page NOTE: To access some components, you may need to remove the cable management arm. Swing open the cable management arm.

Remove the cables from the cable trough. Remove the cable management arm. The server supports variable fan speeds. The fans operate at minimum speed until a temperature change requires a fan speed increase to cool the server. If the cautionary temperature level is still detected after 5 minutes, the BIOS performs an orderly shutdown and enters Standby mode. If the server detects a critical temperature level before the orderly shutdown occurs, the server performs an immediate shutdown.

Additionally, the Health Driver performs an orderly shutdown if more than one fan is failed or removed. Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and running with support packages tailored specifically for HP ProLiant systems. HP Care Packs let you integrate both hardware and software support into a single package.

A number of service level options are available to meet your needs. HP Care Pack Services offer upgraded service levels to expand your standard product warranty with easy- to-buy, easy-to-use support packages that help you make the most of your server investments.

Some of the Care Pack services are:. The rack resource kit ships with all HP branded or Compaq branded , , and H9 series racks. For more information on the content of each resource, refer to the rack resource kit documentation. When installing the server in a rack, select a location that meets the environmental standards described in this section. To allow for servicing and adequate airflow, observe the following space and airflow requirements when deciding where to install a rack:.

HP servers draw in cool air through the front door and expel warm air through the rear door. Therefore, the front and rear rack doors must be adequately ventilated to allow ambient room air to enter the cabinet, and the rear door must be adequately ventilated to allow the warm air to escape from the cabinet.

When vertical space in the rack is not filled by a server or rack component, the gaps between the components cause changes in airflow through the rack and across the servers.

Cover all gaps with blanking panels to maintain proper airflow. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. The and Series Racks provide proper server cooling from flow-through perforations in the front and rear doors that provide 64 percent open area for ventilation.

CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:. To ensure continued safe and reliable equipment operation, install or position the system in a wellventilated, climate-controlled environment. Installation of this equipment must comply with local and regional electrical regulations governing the installation of information technology equipment by licensed electricians.

For electrical power ratings on options, refer to the product rating label or the user documentation supplied with that option.

Consult the electrical authority having jurisdiction over wiring and installation requirements of your facility. This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure. When installing more than one server, you may need to use additional power distribution devices to safely provide power to all devices. Observe the following guidelines:. The server must be grounded properly for proper operation and safety.

In all other countries, you must install the equipment in accordance with any regional or national electrical wiring codes, such as the International Electrotechnical Commission IEC Code , parts 1 through 7. Furthermore, you must be sure that all power distribution devices used in the installation, such as branch wiring and receptacles, are listed or certified grounding-type devices. Using common power outlet strips for the server is not recommended. A rack may become unstable if more than one component is extended for any reason.

An empty 42U rack can weigh as much as kg lb , can stand more than 2. Always handle the rack from both sides. Unpack the server shipping carton and locate the materials and documentation necessary for installing the server. All the rack mounting hardware necessary for installing the server into the rack is included with the rack or the server.

Install any hardware options before initializing the server. For options installation information, refer to the option documentation. For server-specific information, refer to "Hardware options installation on page Install the heaviest item first, and continue to populate the rack from the bottom to the top. Install the server and cable management arm into the rack. For more information, refer to the installation instructions that ship with the 2U Quick Deploy Rail System.

Connect peripheral devices to the server. Connect the power cord to the rear of the server. Install the power cord anchor on the handle of the power supply. NOTE: Peripheral device cables are removed for clarity. Secure cables to the cable management arm. IMPORTANT: When using cable management arm components, be sure to leave enough slack in each of the cables to prevent damage to the cables when the server is extended from the rack.

Connect the power cord to the AC power source. The grounding plug is an important safety feature. Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server. To operate properly, the server must have a supported operating system installed. Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox.

Please check your email for further instructions. Enter a new password. Audience assumptions This document is for the person who installs, administers, and troubleshoots servers and storage systems. Component identification You can only view or download manuals with.

Sign Up and get 5 for free. Upload your files to the site. You get 1 for each file you add. Get 1 for every time someone downloads your manual. Buy as many as you need. View and download manuals available only for.

Register and get 5 for free. Upload manuals that we do not have and get 1 for each file. Get 1 for every download of your manual. Buy as much as you need. To identify component in degraded. To identify component in critical state, refer. To identify component in. If power is off, view the rear panel. Processor in socket X is in a pre-failure condition.

Bank X failed over to the online spare memory bank. Bank s X failed over to the mirrored memory bank s. The Health Driver has detected a cautionary temperature. The server has detected a hardware critical temperature. The drive has failed, or a predictive failure alert has been. Sliding rails and cable management arm for easy serviceability and in-rack tool-less access to major components.

Unit Identification button and LED for easy in rack server identification. Worldwide — Version 50 — September 30, Previous Page. Next Page. HP - ProSignia - Overview 20 pages. Installing and configuring proliant essentials recovery server option rso with oracle database servers 13 pages.

Hp insight diagnostics online edition featuring survey utility and iml viewer 12 pages. Regular firmware updates essential for optimal performance and functionality of hp proliant servers 9 pages.

Remove the riser cage. Locate slot 3, and then remove the expansion slot blank. Install the 12G SAS expander card. The server supports embedded,. If using a type-p Smart Array controller , then install the.

Using the labels on each cable, connect the cables to the SAS expander. For drive numbering, see " Drive bay numbering: SAS expander on page 33". Install the riser cage.